Evaluasi Kualitas Thrombocyte Concentrate (TC) Berdasarkan Kadar pH, Level Kekeruhan, dan Swirling Selama Masa Penyimpanan 5 Hari

  • Aulia Rahman Program Studi Teknologi Bank Darah, STIKES Guna Bangsa Yogyakarta
  • Wiwit Sepvianti Program Studi Teknologi Bank Darah, STIKES Guna Bangsa Yogyakarta
  • Arif Tirtana Program Studi Teknologi Bank Darah, STIKES Guna Bangsa Yogyakarta
  • Gravinda Widyaswara Program Studi Teknologi Bank Darah, STIKES Guna Bangsa Yogyakarta
  • Kumara Rahmawati Zain Program Studi Teknologi Bank Darah, STIKES Guna Bangsa Yogyakarta

Abstract

Thrombocyte concentrate transfusion was one of the important medical treatments in increasing the number of thrombocytes in patients with medical indications of thrombocytopenia. The monitoring of blood product quality from upstream to downstream must be considered in order to obtain a good quality thrombocyte concentrate. Thrombocyte concentrate was prone to change during storage due to significant changes between in vitro and in vivo conditions. The changes in thrombocyte concentrate quality that commonly occur during storage were the decreased platelet levels, increased of acidity (pH) and turbidity, and loss of thrombocyte swirling in the plasma. Therefore, it was necessary to conduct research to determine the quality of thrombocyte concentrates during the 5-day shelf life to find out whether at the end of the shelf life, these blood products were still suitable for transfusion to the patients. Several tools used in this study were Hematology Analyzer, blood scales, and pH meter. The results of successive studies showed that the thrombocyte concentrate product did not meet the basic quality standards because the number of thrombocytes per unit was below the standard that was set by Regulation of the Ministry of Health of the Republic of Indonesia Number 91 Years 2015.

References

A. Kurniawan, “( Studi Kasus Pmi Semarang ),” pp. 1–29, 2010.

N. P. Sari, Purwanto, and Julia, “Residu Leukosit dalam Thrombocyte Concentrate,” Indones. J. Clin. Pathol. Med. Lab., vol. 19, no. 1, pp. 19–23, 2012, [Online]. Available: https://indonesianjournalofclinicalpathology.org/index.php/patologi/article/view/394

W. Sepvianti, M. Wulandari, S. B. C. Kusumaningrum, S. Sunartono, and T. Djafar, “Gambaran Kadar Hemoglobin pada Sediaan Produk Darah Packed Red Cells (PRC) selama Masa Simpan 20 hari,” J. Heal., vol. 6, no. 2, pp. 123–125, 2019, doi: 10.30590/vol6-no2-p123-125.

Y. Andriyani, S. Btari, and W. Sepvianti, “Gambaran Jumlah Eritrosit Pada Whole Blood Selama 30 Hari Penyimpanan Di Pmi Kabupaten Sleman Yogyakarta,” Gambaran Jumlah Eritrosit Pada Whole Blood Selama 30 Hari Penyimpanan Di Pmi Kabupaten Sleman Yogyakarta, vol. d, pp. 463–467, 2018.

N. Lestariyani and S. Herawati, “Perbedaan Jumlah Trombosit Konsentrat Trombosit Pada Penyimpanan Hari I, Iii, V Di Unit Donor Darah Pmi Provinsi Bali/Rsup Sanglah Denpasar,” E-Jurnal Med. Udayana, vol. 6, no. 3, pp. 1–4, 2017.

D. Astuti, “Nilai Indeks Trombosit Sebagai Kontrol Kualitas Komponen Konsentrat Trombosit,” Meditory J. Med. Lab., vol. 8, no. 2, pp. 85–94, 2021, doi: 10.33992/m.v8i2.1238.

K. Kesehatan, “Permenkes RI Nomor 91 Tahun 2015,” Kementeri. Kesehat., vol. 13, no. 3, pp. 1576–1580, 2015.

R. Anggini, W. Sepvianti, and M. Wulandari, “Gambaran Jumlah Trombosit pada Sediaan Darah Thrombocyte Concentrate (TC) Selama Masa Simpah 5 Hari,” Conf. Res. Community Serv., pp. 480–484, 2017, [Online]. Available: https://core.ac.uk/download/pdf/267901692.pdf

E. A. Maharani and G. Noviar, Imunohematologi dan Bank Darah, vol. 1, no. 1. 2018.

D. Mentari, R. Pebrina, and D. Nurpratami, “PENGARUH WAKTU SIMPAN TERHADAP PERUBAHAN pH, KADAR GLUKOSA, LAKTAT DEHIDROGENASE (LDH), KALSIUM, MEAN PLATELET VOLUME (MVP) SEBAGAI INDIKATOR KUALITAS THROMBOCYTE CONCENTRATE,” Biomedika, vol. 12, no. 1, pp. 7–15, 2020, doi: 10.23917/biomedika.v12i1.8981.

R. Samad, A. A. Abdullah, K. A.P., and M. Arif, “Waktu Penyimpanan Trombosit Terkait Jumlah Di Konsentrat Trombosit,” Indones. J. Clin. Pathol. Med. Lab., vol. 20, no. 3, p. 224, 2016, doi: 10.24293/ijcpml.v20i3.481.

S. Sultan, H. A. Zaheer, U. Waheed, M. A. Baig, A. Rehan, and S. M. Irfan, “Internal quality control of blood products: An experience from a tertiary care hospital blood bank from Southern Pakistan,” J. Lab. Physicians, vol. 10, no. 01, pp. 064–067, 2018, doi: 10.4103/jlp.jlp_97_17.

Published